For globe valves in operation, all components must be present and in good condition. Bolts on flanges and brackets must be complete, with threads intact and no signs of loosening. Any loose retaining nuts on handwheels should be tightened promptly to prevent wear at the connection points or the loss of the handwheel or nameplate. If a handwheel is missing, it must be replaced immediately; using an adjustable wrench as a substitute is not permitted. Packing glands must not be misaligned, and there must be an appropriate pre-tightening gap. In environments exposed to rain, snow, dust, or sand, valve stems should be fitted with protective covers. Any scales or indicators on the valve must remain intact, accurate, and legible. Seals (lead seals), caps, and pneumatic accessories must also be complete and in good condition. It is strictly forbidden to strike, stand on, or place heavy objects upon a globe valve while it is in operation-this is especially critical for non-metallic or cast-iron valves. Professional maintenance-including the application of valve grease-performed before welding, prior to commissioning, and throughout the operational phase, is vital for ensuring the valve performs its intended function and extending its service life. While valve maintenance may appear simple, it is often more complex than it seems, with certain aspects frequently overlooked.
First, the issue of grease quantity is often neglected during the lubrication of globe valves. Operators sometimes proceed with lubrication without accurately determining the required amount. This leads to two potential problems: insufficient grease, which accelerates wear on sealing surfaces due to a lack of lubrication; or excessive grease, which results in waste. This often stems from a failure to calculate the precise sealing capacity based on the specific type and category of the globe valve. The sealing capacity can be determined by considering the valve's size and category, allowing for the application of an appropriate, calculated amount of lubricant.
Second, the issue of pressure is frequently overlooked during the lubrication process. When injecting grease, the injection pressure typically fluctuates, exhibiting a pattern of peaks and valleys. Excessively low pressure often indicates a leak or failure in the sealing system, while excessively high pressure may point to a blocked grease injection port, the hardening of grease within the seal, or the seizing of the sealing ring against the valve ball or disc. When injection pressure is too low-a common occurrence in small gate valves-the lubricant often flows into the bottom of the valve cavity. If injection pressure is too high, first check the grease injection fitting; if it is clogged, replace it. If the grease has hardened, use a cleaning agent to soften the degraded lubricant, then flush it out and replace it with fresh grease. Furthermore, the type and material of the seal also influence the required injection pressure; generally, "hard" seals require higher injection pressure than "soft" seals. Ball valves are typically maintained in the open position, though they may be closed for maintenance under specific circumstances. This does not apply to all valve types; for instance, gate valves must be in the closed position during maintenance to ensure that the lubricant fills the sealing grooves along the sealing rings. If a gate valve is left open, the grease will simply fall into the flow passage or valve cavity, resulting in waste.
Following installation, globe valves should be inspected periodically. Key inspection points include:
(1) The wear condition of the globe valve's sealing surfaces.
(2) The wear on the trapezoidal threads of the valve stem and stem nut.
(3) The condition of the packing; if it is aged or ineffective, it should be replaced promptly.
(4) After any maintenance or reassembly, the globe valve must undergo a seal performance test.