(1) The structure of a globe valve is simpler than that of a gate valve, making it easier to manufacture and maintain.
(2) The sealing surfaces are resistant to wear and scuffing. Since there is no relative sliding between the valve disc and the valve body's sealing surface during opening and closing, wear and scuffing are minimal, resulting in excellent sealing performance and a long service life.
(3) The travel distance of the valve disc during opening and closing is short; consequently, globe valves are shorter in height than gate valves, though their overall structural length is greater.
(4) The torque required for opening and closing is high, making the operation more laborious and time-consuming.
(5) Fluid resistance is high; because the flow passage within the valve body is relatively tortuous, the fluid encounters significant resistance, leading to higher power consumption.
(6) Regarding the direction of medium flow: for a nominal pressure (PN) of ≤16 MPa, a "forward flow" configuration is typically used, where the medium flows from beneath the valve disc upward. For a nominal pressure (PN) of ≥20 MPa, a "reverse flow" configuration is generally employed, with the medium flowing from above the valve disc downward, which enhances sealing performance. In operation, the medium in a globe valve can only flow in one direction; the direction of flow cannot be reversed.
(7) When the valve is fully open, the valve disc is frequently subject to erosion.